Shopping on line can be easy, simple and save you lots of money. It can also take a lot of your time, frustrate you, and result in unwanted purchases. Now the same can be said for regular high street shopping, but with the vast opportunity presented by the Internet it will pay you to spend a few minutes reading this and understanding how to better optimize your Standard Temperature And Pressure shopping experience:
1. Compare - without doubt the biggest advantage that the Standard Temperature And Pressure offers shoppers today is the ability to compare thousands of Standard Temperature And Pressure at a time. This is a great thing, but not necessarily all the time! Too much can be daunting at times so take advantage of the great comparison sites and where possible let them do the hard work for you.
2. Research - if it has been said it will be on the internet. Ignorance is no longer a justifiable reason for buying the wrong thing. Take the time to research in detail everything that you could possible want to know about
3. Testimonials - don't know anybody that has bought a Standard Temperature And Pressure? Wrong! If the Standard Temperature And Pressure is good the internet will let you know. Use the Internet as a friend and get testimonials before you buy.
4. Questions - Got a question about Standard Temperature And Pressure then search the Forums, FAQ's, Blogs etc. Don't be afraid to ask .....
5. Reputation - Never heard of the company selling Standard Temperature And Pressure? Don't worry, no reason why you should know every company in the world, but you know someone that does! Use the internet to find out what people are saying about Standard Temperature And Pressure and build up a picture of their reputation for sales, returns, customer service, delivery etc.
6. Returns - still worried that even after all of the above your Standard Temperature And Pressure wont be what you want? Check out the returns policy. There is so much competition now that someone, somewhere is bound to offer the terms that you are comfortable with.
7. Feedback - happy with your Standard Temperature And Pressure then let people know, after all you are depending on others people input in your buying decision, so why not give a little back.
8. Security - check for the yellow padlock on the Standard Temperature And Pressure site before you buy, and the s after http:/ /i.e. https:// = a secure site
9. Contact - got a question about Standard Temperature And Pressure, or want to leave a comment then check out the sites contact page. Reputable companies have them and respond.
10. Payment - ready to pay for your Standard Temperature And Pressure, then use your credit card or PayPal! Be aware of companies that don't accept them, there may be genuine reasons but given the huge amount of choice you have when buying online there is no reason at all not to buy via credit card or PayPal.
In
chemistry and other
sciences,
STP or
standard temperature and pressure is a standard set of conditions for experimental measurements, to enable comparisons to be made between sets of data. Internationally, the current STP defined by the
IUPAC (International Union of Pure and Applied Chemistry) is an absolute
pressure of 100.00 kPa (1 bar) and a
temperature of 273.15 Kelvin (0 °C)."Compendium of Terminology", 2nd Edition, 1997, IUPAC Secretariat, Research Triangle Park, P.O. Box 13757, NC, USA (former and present definitions) IUPAC Compendium Other organizations have established a variety of alternative definitions for the
standard reference conditions of temperature and pressure, such as the
SATP amongst others.
In
industry and commerce, it is necessary to define the standard reference conditions of temperature and pressure when expressing a gas volume or a volumetric flow rate because the volume of a gas varies with the temperature and pressure of the gas.
The available data on the various definitions of standard reference conditions clearly indicates that the IUPAC's STP is not a universally accepted definition of the standard conditions of temperature and pressure. For that reason, simply stating that a gas flow rate is 10,000 m³/h (i.e. cubic meters per hour) at "standard conditions" or at "STP" has no meaning unless the reference conditions that were applied are clearly stated.
In aeronautics and fluid dynamics the term "International Standard Atmosphere" is often used to denote the variation of the principal thermodynamic variables (pressure, temperature, density, etc.) of the atmosphere
with altitude at mid latitudes.
Definitions used in the past
For a great many years, most engineers, chemists, physicists and other scientists using the metric system of units defined the standard reference conditions of temperature and pressure for expressing gas volumes as being 0 °C (273.15
Kelvin) and 101.325
kPa (i.e., 1 Atmosphere (unit) of absolute pressure). During those same years, the most commonly used standard reference conditions for people using the
Imperial unit or U.S. customary unit was 60
Fahrenheit (520
Rankine scale) and 14.696
Pound-force per square inch (i.e., 1 atmosphere of absolute pressure) because it was almost universally used by the oil and gas industries worldwide.
The above two definitions are no longer the most commonly used definitions in either the metric, Imperial or the customary USA system of units. Some of the many different definitions currently in use are presented in the next section.
It was also common in the past, when using the metric system of units, to refer to a
Normal Cubic Meter (Nm³) and to define it as being at 0 °C (273.15 K) and 101.325 kPa (i.e. 1 atmosphere of absolute pressure). As shown in the following section, that notation is no longer appropriate unless the specific reference conditions are explicitly stated, since there are currently many different metric system definitions of what constitutes standard reference conditions.
In the same manner, it is also no longer appropriate to refer to a
standard cubic foot (scf) unless the specific reference conditions are explicitly stated, again because there are currently many different definitions of the standard reference condition in both the Imperial and the customary U.S. systems of units. In particular, Organization of the Petroleum Exporting Countries and a majority of the natural gas industry in North America have adopted 60 °F and 14.73 psia as their standard reference conditions for expressing natural gas volumes and flow rates (rather than the 60 °F and 14.696 psia commonly used previously).
Definitions in current use
There are a great many different definitions of the standard reference conditions currently being used. Table 1 presents twelve such variations of standard condition definitions - and there are quite a few others as well.
As shown in the table, the
IUPAC (International Union of Pure and Applied Chemistry) currently defines standard reference conditions as being 0 °C and 1 bar (i.e., 100 kPa) of absolute pressure rather than the 1 atmosphere (i.e. 101.325 kPa) of absolute pressure used in the past. In fact, the IUPAC's current definition has been in existence since 1982.IUPAC recommended standard pressure of 1 bar in 1982 IUPAC Compendium
As further shown in the table, the oil and gas industries have to a large extent changed from their past usage of 60 °F and 14.696 psia to their current usage of 60 °F and 14.73 psia. This is especially true of the natural gas industry in North America.
For the
SATP used in presenting chemical thermodynamic properties (such as those published by the
National Bureau of Standards as included in Table 1) that the pressure is standardized at 1 bar (100 kPa) but the temperature may vary and needs to be specified separately.
It should also be noted that the International Organization for Standardization (ISO), the
United States Environmental Protection Agency (EPA) and National Institute of Standards and Technology (NIST) each have more than one definition of standard reference conditions in their various standards and regulations.
The table makes it quite obvious that
it is absolutely necessary to clearly state the temperature and pressure reference conditions whenever expressing a gas volume or gas volumetric flowrate. It is equally important to state whether the gas volume is expressed on a dry basis or a wet basis. As noted in the table, some of the current definitions of the reference conditions include a specification of the percent relative humidity (% RH).
{], Geneva, Switzerland ISO|-|align="center"|15||align="center"|101.325||align="center"|0 , ||ISA,"Handbook of Physics and Chemistry", 56th Edition, pp.F201-F206, CRC Press, Boca Raton, FL, USA ISO 13443,"Natural gas – Standard reference conditions", ISO 13443, International Organization for Standardization, Geneva, Switzerland ISO EEA,"Extraction, First Treatment and Loading of Liquid & Gaseous Fossil Fuels", Emission Inventory Guidebook B521, Activities 050201 - 050303, September 1999, European Environmental Agency, Copenhagen, Denmark Emission Inventory Guidebook EGIA"Electricity and Gas Inspection Act", SOR/86-131 (defines a set of standard conditions for Imperial units and a different set for metric units) Canadian Laws|-|align="center"|20||align="center"|101.325|| ||EPA,"Standards of Performance for New Sources", 40 CFR--Protection of the Environment, Chapter I, Part 60, Section 60.2, 1990 New Source Performance Standards NIST"Design and Uncertainty for a PVTt Gas Flow Standard", Journal of Research of the National Institute of Standards and Technology, Vol.108, Number 1, 2003 NIST Journal|-|align="center"|25||align="center"|101.325|| ||EPA"National Primary and Secondary Ambient Air Quality Standards", 40 CFR--Protection of the Environment, Chapter I, Part 50, Section 50.3, 1998 National Ambient Air Standards|-|align="center"|25||align="center"|100.000|| ||SATP"Table of Chemical Thermodynamic Properties", National Bureau of Standards (NBS), Journal of Physics and Chemical Reference Data, 1982, Vol. 11, Supplement 2.|-|align="center"|20||align="center"|100.000||align="center"|0||CAGI"Glossary", 2002, Compressed Air and Gas Institute, Cleveland, OH, USA Glossary|-|align="center"|15||align="center"|100.000|| ||SPE"The SI Metric System of Units and SPE Metric Standard (Notes for Table 2.3 on page 25)", June 1982, Richardson, TX, USA (defines standard cubic foot and standard cubic meter) SPE|-!°F!!psia!! % RH|-|align="center"|60||align="center"|14.696|| ||SPE, OSHA,"Storage and Handling of Liquefied Petroleum Gases" and "Storage and Handling of Anhydrous Ammonia", 29 CFR--Labor, Chapter XVII--Occupational Safety and Health Administration, Part 1910, Sect. 1910.110 and 1910.111, 1993 Storage/Handling of LPG SCAQMD"Rule 102, Definition of Terms (Standard Conditions)", Amended December 2004, South Coast Air Quality Management District, Los Angeles, California, USA SCAQMD Rule 102|-|align="center"|60||align="center"|14.73|| ||EGIA, OPEC,"Annual Statistical Bulletin", 2004, Editor-in-chief: Dr. Omar Ibrahim, Organization of the Petroleum Exporting Countries, Vienna, Austria OPEC Statistical Bulletin EIA"Natural Gas Annual 2004", DOE/EIA-0131(04), December 2005, U.S. Department of Energy, Energy Information Administration, Washington, D.C., USA Natural Gas Annual 2004|-|align="center"|59||align="center"|14.503||align="center"|78||Army Standard Metro"Effects of Altitude and Atmospheric Conditions", Exterior Ballistics Section, Sierra's "Rifle and Handgun Reloading Manual, 5th Edition", Sedalia, MO, USA Exterior Ballistics|-|align="center"|59||align="center"|14.696||align="center"|60||ISO 2314, ISO 3977-2"Gas turbines – Procurement – Part 2: Standard reference conditions and ratings", ISO 3977-2:1997 and "Gas turbines - Acceptance tests", ISO 2314:1989, Edition 2, International Organization for Standardization, Geneva, Switzerland ISO|-!°F!!mmHg!! % RH|-|align="center"|70||align="center"|29.92||align="center"|0||AMCAANSI/AMCA Standard 210, "Laboratory Methods Of Testing Fans for Aerodynamic Performance Rating", as implied here: http://www.greenheck.com/pdf/centrifugal/Plug.pdf when accessed on October 17, 2007, air density = 0.075 lbm/ft3|}
Notes:
- 101.325 kPa = 1 atmosphere = 1.01325 bar ≈ 14.696 psi
- 100.000 kPa = 1 bar ≈ 14.504 psi
- 14.503 psi ≈ 750 mmHg ≈ 100.0 kPa ≈ 1 bar
- 14.696 psi ≈ 1 atm = 101.325 kPa
- 14.73 psi ≈ 30 inHg ≈ 1.0156 bar ≈ 101.560 kPa
- All pressures are absolute pressures (not gauge pressures)
- 59 °F = 15 °C
- 60 °F ≈ 15.6 °C
- dry = 0 percent relative humidity = 0 % RH
The full names of the entities listed in Table 1:
- IUPAC: International Union of Pure and Applied Chemistry
- NIST: National Institute of Standards and Technology
- ISA: ICAO's International Standard Atmosphere
- ISO: International Organization for Standardization
- EEA: European Environment Agency
- EGIA: Electricity and Gas Inspection Act (of Canada)
- EPA: United States Environmental Protection Agency
- SATP: Standard Ambient Pressure and Temperature
- CAGI: CAGI
- SPE: Society of Petroleum Engineers
- OSHA: U.S. Occupational Safety and Health Administration
- SCAQMD: California's South Coast Air Quality Management District
- OPEC: Organization of Petroleum Exporting Countries
- EIA: U.S. Energy Information Administration
- Std. Metro: U.S. Army's Standard Metro (used in ballistics)
- AMCA: Air Movement and Control Association This AMCA standard applies only to air.
Molar volume of a gas
It is equally as important to indicate the applicable reference conditions of temperature and pressure when stating the molar volume of a gas Fundamental Physical Properties: Molar Volumes (CODATA values for ideal gases as listed on a NIST website page) as it is when expressing a gas volume or volumetric flow rate. Stating the molar volume of a gas without indicating the reference conditions of temperature and pressure has no meaning and it can cause much confusion.
The molar gas volumes can be calculated with an accuracy that is usually sufficient by using the universal gas law for ideal gases. The usual expression is:
P \cdot V = n \cdot R \cdot T
…which can be rearranged thus:
\frac{V}{n} = \frac{R \cdot T}{P}
where (in SI metric units):{]|-!align=right|
n|align=left|= number of moles, in mole (unit)|-!align=right|
V /
n|align=left|= the gas molar volume, in m³/mol|-!align=right|
T|align=left|= the gas absolute temperature, in kelvin|-!align=right|
R|align=left|= the gas constant of 8.3145 m³·Pa/(mol·K)|}or where (in customary USA units):{| border="0" cellpadding="2"|-!align=right|
P|align=left|= the gas absolute pressure, in
pound-force per square inch|-!align=right|
n|align=left|= number of moles, in mole (unit)|-!align=right|
V /
n|align=left|= the gas molar volume, in ft³/lbmol|-!align=right|
T|align=left|= the gas absolute temperature, in
Rankine scale|-!align=right|
R|align=left|= the universal gas law constant of 10.7316 ft³·psia/(lbmol·°R)|}
The molar volume of any ideal gas may be calculated at various standard reference conditions as shown below:
- V / n = 8.3145 × 273.15 / 101.325 = 22.414 m³/kmol at 0 °C and 101.325 kPa absolute pressure
- V / n = 8.3145 × 273.15 / 100.000 = 22.711 m³/kmol at 0 °C and 100 kPa absolute pressure
- V / n = 10.7316 × 519.67 / 14.696 = 379.48 ft³/lbmol at 60 °F and 14.696 psia absolute pressure
- V / n = 10.7316 × 519.67 / 14.730 = 378.61 ft³/lbmol at 60 °F and 14.73 psia absolute pressure
The technical literature can be very confusing because many authors fail to explain whether they are using the universal gas law constant
R which applies to any ideal gas or whether they are using the gas law constant
Rs which only applies to a specific individual gas. The relationship between the two constants is
Rs =
R / M, where
M is the molecular weight of the gas.
It may be of interest to note that the US Standard Atmosphere still uses 8.31432 m³·Pa/(mol·K) as the value of R for all calculations. (See
Gas constant#US Standard Atmosphere)
References
External links
- "Standard conditions for gases" from the IUPAC Gold Book.
- "Standard pressure" from the IUPAC Gold Book.
- "STP" from the IUPAC Gold Book.
- "Standard state" from the IUPAC Gold Book.
In chemistry and other sciences,
STP or
standard temperature and pressure is a standard set of conditions for experimental measurements, to enable comparisons to be made between sets of data. Internationally, the current STP defined by the IUPAC (International Union of Pure and Applied Chemistry) is an absolute
pressure of 100.00
kPa (1 bar) and a temperature of 273.15
Kelvin (0 °C)."Compendium of Terminology", 2nd Edition, 1997, IUPAC Secretariat, Research Triangle Park, P.O. Box 13757, NC, USA (former and present definitions) IUPAC Compendium Other organizations have established a variety of alternative definitions for the
standard reference conditions of temperature and pressure, such as the
SATP amongst others.
In industry and commerce, it is necessary to define the standard reference conditions of temperature and pressure when expressing a gas volume or a volumetric flow rate because the volume of a gas varies with the temperature and pressure of the gas.
The available data on the various definitions of standard reference conditions clearly indicates that the IUPAC's STP is not a universally accepted definition of the standard conditions of temperature and pressure. For that reason, simply stating that a gas flow rate is 10,000 m³/h (i.e. cubic meters per hour) at "standard conditions" or at "STP" has no meaning unless the reference conditions that were applied are clearly stated.
In
aeronautics and fluid dynamics the term "
International Standard Atmosphere" is often used to denote the variation of the principal
thermodynamic variables (pressure, temperature, density, etc.) of the atmosphere
with altitude at mid latitudes.
Definitions used in the past
For a great many years, most engineers, chemists, physicists and other scientists using the metric system of units defined the standard reference conditions of temperature and pressure for expressing gas volumes as being 0 °C (273.15 Kelvin) and 101.325
kPa (i.e., 1
Atmosphere (unit) of absolute pressure). During those same years, the most commonly used standard reference conditions for people using the
Imperial unit or
U.S. customary unit was 60
Fahrenheit (520
Rankine scale) and 14.696
Pound-force per square inch (i.e., 1 atmosphere of absolute pressure) because it was almost universally used by the oil and gas industries worldwide.
The above two definitions are no longer the most commonly used definitions in either the metric, Imperial or the customary USA system of units. Some of the many different definitions currently in use are presented in the next section.
It was also common in the past, when using the metric system of units, to refer to a
Normal Cubic Meter (Nm³) and to define it as being at 0 °C (273.15 K) and 101.325 kPa (i.e. 1 atmosphere of absolute pressure). As shown in the following section, that notation is no longer appropriate unless the specific reference conditions are explicitly stated, since there are currently many different metric system definitions of what constitutes standard reference conditions.
In the same manner, it is also no longer appropriate to refer to a standard cubic foot (scf) unless the specific reference conditions are explicitly stated, again because there are currently many different definitions of the standard reference condition in both the Imperial and the customary U.S. systems of units. In particular, Organization of the Petroleum Exporting Countries and a majority of the natural gas industry in North America have adopted 60 °F and 14.73 psia as their standard reference conditions for expressing natural gas volumes and flow rates (rather than the 60 °F and 14.696 psia commonly used previously).
Definitions in current use
There are a great many different definitions of the standard reference conditions currently being used. Table 1 presents twelve such variations of standard condition definitions - and there are quite a few others as well.
As shown in the table, the IUPAC (International Union of Pure and Applied Chemistry) currently defines standard reference conditions as being 0 °C and 1 bar (i.e., 100 kPa) of absolute pressure rather than the 1 atmosphere (i.e. 101.325 kPa) of absolute pressure used in the past. In fact, the IUPAC's current definition has been in existence since 1982.IUPAC recommended standard pressure of 1 bar in 1982 IUPAC Compendium
As further shown in the table, the oil and gas industries have to a large extent changed from their past usage of 60 °F and 14.696 psia to their current usage of 60 °F and 14.73 psia. This is especially true of the natural gas industry in North America.
For the
SATP used in presenting chemical thermodynamic properties (such as those published by the
National Bureau of Standards as included in Table 1) that the pressure is standardized at 1 bar (100 kPa) but the temperature may vary and needs to be specified separately.
It should also be noted that the
International Organization for Standardization (ISO), the United States Environmental Protection Agency (EPA) and
National Institute of Standards and Technology (NIST) each have more than one definition of standard reference conditions in their various standards and regulations.
The table makes it quite obvious that
it is absolutely necessary to clearly state the temperature and pressure reference conditions whenever expressing a gas volume or gas volumetric flowrate. It is equally important to state whether the gas volume is expressed on a dry basis or a wet basis. As noted in the table, some of the current definitions of the reference conditions include a specification of the percent relative humidity (% RH).
{], Geneva, Switzerland ISO|-|align="center"|15||align="center"|101.325||align="center"|0 , ||ISA,"Handbook of Physics and Chemistry", 56th Edition, pp.F201-F206, CRC Press, Boca Raton, FL, USA ISO 13443,"Natural gas – Standard reference conditions", ISO 13443, International Organization for Standardization, Geneva, Switzerland ISO EEA,"Extraction, First Treatment and Loading of Liquid & Gaseous Fossil Fuels", Emission Inventory Guidebook B521, Activities 050201 - 050303, September 1999, European Environmental Agency, Copenhagen, Denmark Emission Inventory Guidebook EGIA"Electricity and Gas Inspection Act", SOR/86-131 (defines a set of standard conditions for Imperial units and a different set for metric units) Canadian Laws|-|align="center"|20||align="center"|101.325|| ||EPA,"Standards of Performance for New Sources", 40 CFR--Protection of the Environment, Chapter I, Part 60, Section 60.2, 1990 New Source Performance Standards NIST"Design and Uncertainty for a PVTt Gas Flow Standard", Journal of Research of the National Institute of Standards and Technology, Vol.108, Number 1, 2003 NIST Journal|-|align="center"|25||align="center"|101.325|| ||EPA"National Primary and Secondary Ambient Air Quality Standards", 40 CFR--Protection of the Environment, Chapter I, Part 50, Section 50.3, 1998 National Ambient Air Standards|-|align="center"|25||align="center"|100.000|| ||SATP"Table of Chemical Thermodynamic Properties", National Bureau of Standards (NBS), Journal of Physics and Chemical Reference Data, 1982, Vol. 11, Supplement 2.|-|align="center"|20||align="center"|100.000||align="center"|0||CAGI"Glossary", 2002, Compressed Air and Gas Institute, Cleveland, OH, USA Glossary|-|align="center"|15||align="center"|100.000|| ||SPE"The SI Metric System of Units and SPE Metric Standard (Notes for Table 2.3 on page 25)", June 1982, Richardson, TX, USA (defines standard cubic foot and standard cubic meter) SPE|-!°F!!psia!! % RH|-|align="center"|60||align="center"|14.696|| ||SPE, OSHA,"Storage and Handling of Liquefied Petroleum Gases" and "Storage and Handling of Anhydrous Ammonia", 29 CFR--Labor, Chapter XVII--Occupational Safety and Health Administration, Part 1910, Sect. 1910.110 and 1910.111, 1993 Storage/Handling of LPG SCAQMD"Rule 102, Definition of Terms (Standard Conditions)", Amended December 2004, South Coast Air Quality Management District, Los Angeles, California, USA SCAQMD Rule 102|-|align="center"|60||align="center"|14.73|| ||EGIA, OPEC,"Annual Statistical Bulletin", 2004, Editor-in-chief: Dr. Omar Ibrahim, Organization of the Petroleum Exporting Countries, Vienna, Austria OPEC Statistical Bulletin EIA"Natural Gas Annual 2004", DOE/EIA-0131(04), December 2005, U.S. Department of Energy, Energy Information Administration, Washington, D.C., USA Natural Gas Annual 2004|-|align="center"|59||align="center"|14.503||align="center"|78||Army Standard Metro"Effects of Altitude and Atmospheric Conditions", Exterior Ballistics Section, Sierra's "Rifle and Handgun Reloading Manual, 5th Edition", Sedalia, MO, USA Exterior Ballistics|-|align="center"|59||align="center"|14.696||align="center"|60||ISO 2314, ISO 3977-2"Gas turbines – Procurement – Part 2: Standard reference conditions and ratings", ISO 3977-2:1997 and "Gas turbines - Acceptance tests", ISO 2314:1989, Edition 2, International Organization for Standardization, Geneva, Switzerland ISO|-!°F!!mmHg!! % RH|-|align="center"|70||align="center"|29.92||align="center"|0||AMCAANSI/AMCA Standard 210, "Laboratory Methods Of Testing Fans for Aerodynamic Performance Rating", as implied here: http://www.greenheck.com/pdf/centrifugal/Plug.pdf when accessed on October 17, 2007, air density = 0.075 lbm/ft3|}
Notes:
- 101.325 kPa = 1 atmosphere = 1.01325 bar ≈ 14.696 psi
- 100.000 kPa = 1 bar ≈ 14.504 psi
- 14.503 psi ≈ 750 mmHg ≈ 100.0 kPa ≈ 1 bar
- 14.696 psi ≈ 1 atm = 101.325 kPa
- 14.73 psi ≈ 30 inHg ≈ 1.0156 bar ≈ 101.560 kPa
- All pressures are absolute pressures (not gauge pressures)
- 59 °F = 15 °C
- 60 °F ≈ 15.6 °C
- dry = 0 percent relative humidity = 0 % RH
The full names of the entities listed in Table 1:
Molar volume of a gas
It is equally as important to indicate the applicable reference conditions of temperature and pressure when stating the molar volume of a gas Fundamental Physical Properties: Molar Volumes (CODATA values for ideal gases as listed on a
NIST website page) as it is when expressing a gas volume or volumetric flow rate. Stating the molar volume of a gas without indicating the reference conditions of temperature and pressure has no meaning and it can cause much confusion.
The molar gas volumes can be calculated with an accuracy that is usually sufficient by using the
universal gas law for ideal gases. The usual expression is:
P \cdot V = n \cdot R \cdot T
…which can be rearranged thus:
\frac{V}{n} = \frac{R \cdot T}{P}
where (in SI metric units):{]|-!align=right|
n|align=left|= number of moles, in
mole (unit)|-!align=right|
V /
n|align=left|= the gas molar volume, in m³/mol|-!align=right|
T|align=left|= the gas absolute temperature, in
kelvin|-!align=right|
R|align=left|= the gas constant of 8.3145 m³·Pa/(mol·K)|}or where (in customary USA units):{| border="0" cellpadding="2"|-!align=right|
P|align=left|= the gas absolute pressure, in
pound-force per square inch|-!align=right|
n|align=left|= number of moles, in
mole (unit)|-!align=right|
V /
n|align=left|= the gas molar volume, in ft³/lbmol|-!align=right|
T|align=left|= the gas absolute temperature, in Rankine scale|-!align=right|
R|align=left|= the universal gas law constant of 10.7316 ft³·psia/(lbmol·°R)|}
The molar volume of any ideal gas may be calculated at various standard reference conditions as shown below:
- V / n = 8.3145 × 273.15 / 101.325 = 22.414 m³/kmol at 0 °C and 101.325 kPa absolute pressure
- V / n = 8.3145 × 273.15 / 100.000 = 22.711 m³/kmol at 0 °C and 100 kPa absolute pressure
- V / n = 10.7316 × 519.67 / 14.696 = 379.48 ft³/lbmol at 60 °F and 14.696 psia absolute pressure
- V / n = 10.7316 × 519.67 / 14.730 = 378.61 ft³/lbmol at 60 °F and 14.73 psia absolute pressure
The technical literature can be very confusing because many authors fail to explain whether they are using the universal gas law constant
R which applies to any ideal gas or whether they are using the gas law constant
Rs which only applies to a specific individual gas. The relationship between the two constants is
Rs =
R / M, where
M is the molecular weight of the gas.
It may be of interest to note that the US Standard Atmosphere still uses 8.31432 m³·Pa/(mol·K) as the value of R for all calculations. (See
Gas constant#US Standard Atmosphere)
References
External links
- "Standard conditions for gases" from the IUPAC Gold Book.
- "Standard pressure" from the IUPAC Gold Book.
- "STP" from the IUPAC Gold Book.
- "Standard state" from the IUPAC Gold Book.
Standard conditions for temperature and pressure - Wikipedia, the free ...
In chemistry and other sciences, STP or standard temperature and pressure is a standard set of conditions for experimental measurements, to enable comparisons to be made between ...
standard temperature and pressure - Hutchinson encyclopedia article ...
standard temperature and pressure. In chemistry, a standard set of conditions for experimental measurements, to enable comparisons to be made between sets of results.
STANDARD TEMPERATURE AND PRESSURE CALCULATOR
Input in Liters Torr and Kelvin, Standard Temperature and Pressure Calculator, Chemistry, Gas Laws, Temperature, Volume, Pressure
Standard temperature and pressure - Engineering
It is absolutely necessary to define the standard reference conditions of temperature and pressure when expressing a gas volume or a volumetric flow rate because the volume of a ...
standard temperature and pressure
In chemistry, a standard set of conditions for experimental measurements, to enable comparisons to be made between sets of results
Effect of temperature and pressure on enzyme activity
Effect of temperature and pressure on enzyme activity ... factors, R is the gas law constant and T is the absolute temperature. Typical standard free ...
What is standard temperature and pressure? - a definition from Whatis ...
Standard temperature and pressure, abbreviated STP, refers to nominal conditions in dry air at sea level.
The MSDS HyperGlossary: Standard Temperature and Pressure (STP)
Entry in the Material Safety Data Sheet HyperGlossary at ILPI. ... Definition. Standard Temperature and Pressure (STP) is defined as 0 degrees Celsius and 1 atmosphere of pressure.
Standard Temperature and Pressure -- from Eric Weisstein's World of ...
Defined as 1 atmosphere of pressure and 0° Celsius (273.15 Kelvin). The density of air is 1.29 kg m-3 at standard temperature and pressure. Standard temperature and pressure is ...
standard temperature and pressure definition of standard temperature ...
standard temperature and pressure: see STP STP or standard temperature and pressure, standard conditions for measurement of the properties of matter.